API

Temperature Monitoring API for Developers

Last updated: 12 October 2026

The Thermalog API lets your own systems read your monitoring data: your sites, their sensors, readings and alarms. Webhooks tell your systems the moment an alarm changes, so you don’t have to poll.

The API is read-only. It works for sites with a Thermalog gateway, not for free or demo sites. It is built for server-to-server use: call it from your backend, never from a web page or app that other people can open.

  • Base URL: https://dashboard.thermalog.com.au/api/v1
  • Interactive reference: /api/v1/docs, with every field of every response
  • OpenAPI document: /api/v1/openapi.json, to generate a client in your language

The reference is built from the running API, so it always matches what is live. This guide explains how the pieces fit together. If the two ever disagree, the reference is right.

On this page: Getting started · API keys · Authentication · Rate limits · Endpoints · Pagination · Errors · Webhooks · Changelog

Getting started

  1. Sign in to the Thermalog dashboard as the Admin of a site with a Thermalog gateway.
  2. Open Settings → You → API access and create a key. Pick the sites it can read.
  3. Copy the key straight away. It is shown once and we cannot show it again.
  4. Check that it works:
export THERMALOG_API_KEY='tl_xxxxxxxxxxxx.your-secret'

curl -s https://dashboard.thermalog.com.au/api/v1/me \
  -H "Authorization: Bearer $THERMALOG_API_KEY"

Keep the key out of source control. Store it the way you store a password, for example in an environment variable or a secrets manager.

API keys

  • Who can create keys. You need the Admin role at a site to give a key access to it. Managers and staff cannot create keys.
  • Keys belong to you. A key belongs to the Admin who created it, not to the business. If your account is deleted, your keys stop working.
  • Sites. A key either names its sites or reads all of your sites:
    • A key that names its sites keeps reading each one while you are an Admin or Manager there.
    • An all-sites key reads every site you are the Admin of, including sites you become the Admin of later.
    • Leaving a site, or becoming a plain user there, stops both kinds of key reading it. A site that is no longer on a Thermalog gateway plan cannot be read either.
  • Shown once. We store only a fingerprint (hash) of the secret part of the key, so nobody at Thermalog can read it back. If you lose a key, rotate it or create a new one.
  • Read-only. Every key in v1 has the read scope. Nothing you do with a key can change your sites, sensors or settings.
  • Expiry. A key can have an expiry date up to two years ahead, or none.
  • Rotation. Rotating gives you a new key. The old one keeps working for up to 24 hours (never past its own expiry date) so you can swap it over without downtime. After that it answers 401 API_KEY_EXPIRED.
  • Revoking. Revoking stops a key straight away. Revoking the new key after a rotation does not stop the old one during its 24 hours. If a secret has leaked, revoke both.
  • Password changes. Changing your password, or signing out on every device, does not revoke your API keys. They are a separate credential. Revoke them on the API access page if you need to.
  • Limits. Up to 20 active keys and 10 webhook endpoints per account.
  • Usage. The API access page shows when each key was last used and how many requests it made in the last 24 hours and 30 days.

Every key starts with tl_, so a secret scanner can be set up to find one that has been committed or pasted somewhere it shouldn’t be. If a key leaks, revoke it.

Authentication

Send the key in the Authorization header of every request:

Authorization: Bearer tl_<publicId>.<secret>
  • Send the header once. A request with more than one Authorization header is refused.
  • A bad, expired or revoked key gets a 401 (see Errors). The response never says whether the key’s id exists.
  • Your dashboard sign-in does not work on the API, and an API key does not work on the dashboard.
  • No browser origin is allowed except Thermalog’s own dashboard, so your web pages cannot call the API. Call it from your server, never from a web page, so the key stays secret.

Rate limits

Limit Applies to
600 requests a minute Each key, on every route except readings
120 requests a minute Each key, on the readings route
3,000 requests a minute All keys together
1,200 requests a minute Each IP address, on each route

A readings request counts against the readings limit and the all-keys limit, not against the 600. The all-keys limit is shared by every customer, so in a very busy minute you can get a 429 before your own limit.

Every response to a valid key carries:

  • X-RateLimit-Limit: your key’s limit for this route, per minute
  • X-RateLimit-Remaining: requests left in the current minute
  • X-RateLimit-Reset: seconds until the window resets

Over a limit, you get 429 with code RATE_LIMITED and a Retry-After header in seconds. Wait that long, then try again.

In front of the API, our edge also refuses bursts of more than 20 requests a second from one address. That 429 has no JSON body and no Retry-After, so treat any 429 the same way: wait a few seconds and try again. The helper below waits 5 seconds when Retry-After is missing.

Two more 503 answers can come back, and they need different handling:

  • 503 BUSY: the API is handling as many requests as it can right now. It sends Retry-After (2 seconds); wait that long and try again.
  • 503 QUERY_TIMEOUT: your request took longer than 5 seconds to answer. Sending it again will not help. Change the request: ask for a shorter range or a longer interval.

A simple way to respect all of this in Python:

import os
import time

import requests

BASE = "https://dashboard.thermalog.com.au/api/v1"
session = requests.Session()
session.headers["Authorization"] = f"Bearer {os.environ['THERMALOG_API_KEY']}"


def get(path, params=None):
    for _ in range(5):
        resp = session.get(BASE + path, params=params, timeout=30)
        retry_after = resp.headers.get("Retry-After")
        # 429, or 503 BUSY (which sends Retry-After). A 503 QUERY_TIMEOUT has no
        # Retry-After and is raised below: change the request instead.
        if resp.status_code == 429 or (resp.status_code == 503 and retry_after):
            time.sleep(int(retry_after or "5"))
            continue
        resp.raise_for_status()
        return resp.json()
    resp.raise_for_status()


print(get("/me"))

The Python examples below use this get helper.

Endpoints

All routes are GET. Query parameters are strict: a parameter the route does not know is refused with 400 INVALID_REQUEST, so a typo cannot be silently ignored.

Times are ISO 8601. Responses give them in UTC. When you send from or to, always include Z or a UTC offset, for example 2026-10-01T00:00:00Z or 2026-10-01T10:00:00+10:00.

Responses contain ids, names, readings, limits and times. They never contain anyone’s email address or phone number, or the hardware addresses of your devices.

Replace 123 (a site id) and 456 (a sensor id) in the examples with ids from your own /sites and /sensors responses.

GET /me

The key making the request: its name, scopes, expiry, rate limits and the sites it can read right now. A cheap way to check that a key works.

curl -s https://dashboard.thermalog.com.au/api/v1/me \
  -H "Authorization: Bearer $THERMALOG_API_KEY"
{
  "name": "Building management system",
  "prefix": "tl_abcdefgh2345.Xy9_",
  "scopes": ["read"],
  "allSites": false,
  "expiresAt": null,
  "createdAt": "2026-10-12T02:30:00.000Z",
  "sites": [{ "siteId": 123, "name": "Main kitchen" }],
  "rateLimits": { "perMinute": 600, "readingsPerMinute": 120 }
}

prefix is the start of the key, as the dashboard shows it. expiresAt is null for a key that never expires.

GET /sites

The sites this key can read, with each site’s time zone, gateway state, sensor counts and open alarm counts.

curl -s https://dashboard.thermalog.com.au/api/v1/sites \
  -H "Authorization: Bearer $THERMALOG_API_KEY"
sites = get("/sites")["sites"]
{
  "sites": [
    {
      "siteId": 123,
      "name": "Main kitchen",
      "timezone": "Australia/Sydney",
      "gatewayType": "hub",
      "gatewayOnline": true,
      "lastReadingAt": "2026-10-12T03:14:00.000Z",
      "sensors": { "online": 6, "total": 6 },
      "alarms": { "open": 1, "muted": 0, "unacknowledged": 1 }
    }
  ]
}
  • gatewayType is hub or tablet, or null when the site has no gateway yet.
  • sensors.total counts the site’s temperature sensors. sensors.online counts those heard from in the last 20 minutes, and is 0 while the gateway is offline.
  • alarms.open counts open temperature, humidity and door alarms, muted ones included. muted and unacknowledged are subsets of it; unacknowledged means neither muted nor acknowledged by anyone.

GET /sites/{siteId}/sensors

Every temperature, humidity and door sensor on the site, with its latest reading, limits and open alarms.

curl -s https://dashboard.thermalog.com.au/api/v1/sites/123/sensors \
  -H "Authorization: Bearer $THERMALOG_API_KEY"
sensors = get("/sites/123/sensors")["sensors"]
{
  "siteId": 123,
  "sensors": [
    {
      "id": 456,
      "unitId": 2201,
      "name": "Walk-in cool room",
      "type": "temperature",
      "unitOfMeasure": "°C",
      "latestValue": 6.2,
      "latestAt": "2026-10-12T03:14:00.000Z",
      "online": true,
      "profileName": "Cool room",
      "limits": { "min": 0, "max": 5 },
      "openAlarms": [
        {
          "id": 88123,
          "category": "temperature",
          "level": "caution",
          "openedAt": "2026-10-12T03:02:00.000Z",
          "muted": false
        }
      ]
    },
    {
      "id": 789,
      "unitId": 2201,
      "name": "Walk-in cool room",
      "type": "door",
      "unitOfMeasure": null,
      "latestValue": 0,
      "latestAt": "2026-10-12T02:58:41.000Z",
      "online": true,
      "profileName": null,
      "limits": null,
      "openAlarms": []
    }
  ]
}
  • type is temperature, humidity or door. A temperature and humidity sensor is two sensors on one unit.
  • unitId is the unit (fridge, freezer, room) the sensor is on.
  • A sensor’s id stays the same for the life of the sensor on its unit, through a gateway or sensor replacement, so it is safe to store.
  • unitOfMeasure is °C or %, and null for a door. A door’s latestValue is 1 for open and 0 for closed.
  • online: a temperature or humidity sensor heard from in the last 20 minutes while the gateway is online. For a door, the gateway is online and the sensor has no offline alarm.
  • limits come from the sensor’s equipment profile (profileName). They are null for a door or a sensor that is not monitored.
  • /sites and /sensors are refreshed at most every 15 seconds. Polling more often returns the same data.

GET /sites/{siteId}/sensors/{sensorId}/readings

A sensor’s readings from from (inclusive) to to (exclusive). Leave to out for now, and from out for 24 hours before to. Choose the shape with interval.

Parameter Values Default
from ISO 8601 time with Z or an offset 24 hours before to
to ISO 8601 time with Z or an offset now
interval 1m, 5m, 15m, 1h, 1d or raw 15m
cursor raw only: the nextCursor of the previous page
limit raw only: readings per page, 1 to 1,000 1,000

Bucketed readings. With interval set to 1m, 5m, 15m, 1h or 1d, you get one entry per bucket in buckets:

curl -s -G https://dashboard.thermalog.com.au/api/v1/sites/123/sensors/456/readings \
  -H "Authorization: Bearer $THERMALOG_API_KEY" \
  --data-urlencode "from=2026-10-01T00:00:00Z" \
  --data-urlencode "to=2026-10-08T00:00:00Z" \
  -d interval=1h
week = get("/sites/123/sensors/456/readings", {
    "from": "2026-10-01T00:00:00Z",
    "to": "2026-10-08T00:00:00Z",
    "interval": "1h",
})
for bucket in week["buckets"]:
    print(bucket["at"], bucket["avg"], bucket["min"], bucket["max"])
{
  "sensorId": 456,
  "type": "temperature",
  "unitOfMeasure": "°C",
  "interval": "1h",
  "from": "2026-10-01T00:00:00.000Z",
  "to": "2026-10-08T00:00:00.000Z",
  "timezone": "Australia/Sydney",
  "buckets": [
    { "at": "2026-10-01T00:00:00.000Z", "avg": 3.4, "min": 2.9, "max": 4.1, "count": 30 },
    { "at": "2026-10-01T01:00:00.000Z", "avg": 3.6, "min": 3.1, "max": 5.8, "count": 30 }
  ],
  "readings": [],
  "nextCursor": null
}
  • at is the start of the bucket, and count is the number of readings in it. The minimum and maximum show a short excursion that an average alone would hide.
  • Buckets with no readings are left out.
  • 1d buckets are days in the site’s time zone (timezone). The other intervals are aligned to UTC.

Raw readings. With interval=raw you get every stored reading in readings, up to 1,000 a page. When there are more, follow nextCursor; see Pagination.

curl -s -G https://dashboard.thermalog.com.au/api/v1/sites/123/sensors/456/readings \
  -H "Authorization: Bearer $THERMALOG_API_KEY" \
  --data-urlencode "from=2026-10-07T00:00:00Z" \
  --data-urlencode "to=2026-10-08T00:00:00Z" \
  -d interval=raw \
  -d limit=2

With limit=2 to keep the example short:

{
  "sensorId": 456,
  "type": "temperature",
  "unitOfMeasure": "°C",
  "interval": "raw",
  "from": "2026-10-07T00:00:00.000Z",
  "to": "2026-10-08T00:00:00.000Z",
  "timezone": "Australia/Sydney",
  "buckets": [],
  "readings": [
    { "at": "2026-10-07T00:01:12.000Z", "value": 3.4 },
    { "at": "2026-10-07T00:03:12.000Z", "value": 3.5 }
  ],
  "nextCursor": "eyJ0IjoiMjAyNi0xMC0wN1QwMDowMzoxMi4wMDBaIn0"
}

Every raw reading in a range, page by page, in Python:

def raw_readings(site_id, sensor_id, start, end):
    # Send the same from and to on every page.
    params = {"from": start, "to": end, "interval": "raw"}
    while True:
        page = get(f"/sites/{site_id}/sensors/{sensor_id}/readings", params)
        yield from page["readings"]
        if page["nextCursor"] is None:
            return
        params["cursor"] = page["nextCursor"]


for reading in raw_readings(123, 456, "2026-10-07T00:00:00Z", "2026-10-08T00:00:00Z"):
    print(reading["at"], reading["value"])

Door sensors. A door has no temperature, so its readings are its changes of state. Whatever interval you send, a door answers "interval": "raw" with every change in readings (value 1 for opened, 0 for closed), all in one response with nextCursor set to null. The range limit still follows the interval you send, so leave interval out to read up to 31 days of a door at once.

door = get("/sites/123/sensors/789/readings", {
    "from": "2026-10-11T00:00:00Z",
    "to": "2026-10-12T00:00:00Z",
})
for change in door["readings"]:
    print(change["at"], "opened" if change["value"] == 1 else "closed")
{
  "sensorId": 789,
  "type": "door",
  "unitOfMeasure": null,
  "interval": "raw",
  "from": "2026-10-11T00:00:00.000Z",
  "to": "2026-10-12T00:00:00.000Z",
  "timezone": "Australia/Sydney",
  "buckets": [],
  "readings": [
    { "at": "2026-10-11T21:05:09.000Z", "value": 1 },
    { "at": "2026-10-11T21:06:40.000Z", "value": 0 }
  ],
  "nextCursor": null
}

Range limits.

  • Bucketed: up to 31 days per request, and no more than 10,000 buckets (a week of 1m buckets is too many; use 5m).
  • Raw: up to 7 days per request.
  • Longer ranges, or too many buckets, are refused with 400 RANGE_TOO_LARGE. Split them into several requests.
  • from must be before to, or you get 400 INVALID_RANGE.

Readings requests count against the readings limit of 120 a minute per key and the all-keys limit of 3,000 a minute, not against the 600 a minute that covers the other routes.

GET /sites/{siteId}/alarms

The alarms opened at a site from from (inclusive) to to (exclusive), newest first. A window can be up to 92 days.

Parameter Values Default
from ISO 8601 time with Z or an offset 7 days before to
to ISO 8601 time with Z or an offset now
status open or closed both
cursor the nextCursor of the previous page
limit alarms per page, 1 to 200 100
curl -s -G https://dashboard.thermalog.com.au/api/v1/sites/123/alarms \
  -H "Authorization: Bearer $THERMALOG_API_KEY" \
  -d status=open
recent_open_alarms = get("/sites/123/alarms", {"status": "open"})["alarms"]

status=open returns the alarms still open that were opened inside the window, so with the default window an alarm opened 8 days ago and still open is missing. To see everything open now, read each sensor’s openAlarms from /sensors, plus gatewayOnline for each site from /sites: a gateway outage is not on any sensor (webhooks send it as gateway.offline and gateway.online). Or set from up to 92 days before to and follow nextCursor.

{
  "siteId": 123,
  "from": "2026-10-05T03:15:00.000Z",
  "to": "2026-10-12T03:15:00.000Z",
  "alarms": [
    {
      "id": 88123,
      "siteId": 123,
      "category": "temperature",
      "level": "caution",
      "status": "open",
      "sensorId": 456,
      "unitId": 2201,
      "sensorName": "Walk-in cool room",
      "openedAt": "2026-10-12T03:02:00.000Z",
      "mutedAt": null,
      "closedAt": null,
      "closeReason": null
    }
  ],
  "nextCursor": null
}
  • category is temperature, humidity or door (out of limits or left open), sensor (the sensor stopped reporting) or gateway (the site’s hub or tablet went offline).
  • level is the worst the alarm reached: warning, caution or info.
  • status is open or closed. A muted alarm is still open; mutedAt says since when.
  • sensorId, unitId and sensorName are null for a gateway alarm.
  • closeReason says why the alarm ended, and is null while it is open. See the reference for its values.
  • Energy-use alerts are not included.

Pagination

Raw readings and alarms come in pages. A response with more results after it has a nextCursor. Send it back unchanged as the cursor parameter to get the next page. When nextCursor is null, you have the last page.

Send the same from, to and other parameters on every page. If you leave from or to out, they default to times relative to now, which move between one page and the next. Pass fixed times when you page.

Cursors are opaque. Don’t build or edit one: a malformed cursor, or one we did not hand out, may be refused with 400 INVALID_CURSOR. So is any cursor sent with bucketed readings or to a door, which have no pages.

Errors

Every error has the same JSON body:

{ "statusCode": 404, "code": "SITE_NOT_FOUND", "message": "Site not found." }

Branch on code, not on message; messages are written for people and may change. A 400 INVALID_REQUEST usually carries details, a list of what is wrong with each parameter:

{
  "statusCode": 400,
  "code": "INVALID_REQUEST",
  "message": "The request is not valid. See details.",
  "details": ["property foo should not exist"]
}
Code Status Meaning
INVALID_API_KEY 401 The key is missing, malformed or wrong, or its owner’s account is gone
API_KEY_EXPIRED 401 The key has passed its expiry date, or its grace period after a rotation has ended
API_KEY_REVOKED 401 The key has been revoked
INSUFFICIENT_SCOPE 403 The key’s scope does not allow this request
KEY_SITE_NOT_ALLOWED 403 The site is on the key, but the key’s owner is no longer an Admin or Manager there
PAID_SITE_REQUIRED 403 The site has no Thermalog gateway plan (a free or demo site)
FORBIDDEN 403 Refused, without a more specific code
SITE_NOT_FOUND 404 The key does not read this site. We don’t say whether it exists, so one customer cannot discover another’s sites
SENSOR_NOT_FOUND 404 The sensor is not on this site
NOT_FOUND 404 Not found, without a more specific code
INVALID_REQUEST 400 A parameter is missing, malformed or unknown. Usually with details
INVALID_RANGE 400 from is not before to
RANGE_TOO_LARGE 400 The window is longer than the route allows, or makes more than 10,000 buckets. See range limits
INVALID_CURSOR 400 The cursor is malformed or not one we handed out, or this request has no pages
RATE_LIMITED 429 Over a rate limit. Wait for Retry-After
BUSY 503 The API is at capacity. Wait for Retry-After
QUERY_TIMEOUT 503 The request took longer than 5 seconds. Ask for less data
INTERNAL 500 Something went wrong on our side. We are notified automatically

Webhooks

A webhook sends an HTTPS POST to your server when something happens at your sites. You manage webhooks in Settings → You → API access, the same place as your keys. Add a webhook, choose its events and sites, and copy its signing secret. The secret starts with whsec_ and is shown in full once; after that the dashboard shows its last four characters.

Webhooks are sent the moment an alarm changes. Email, SMS and push alerts to people can be held back or grouped: grace periods, quiet hours, a pause before an all-clear. Webhooks skip all of that. So your system may hear about a short alarm that never reached anyone’s phone. Alarms that a tablet uploads later from its history do not send webhooks.

Use the webhook’s Test button to receive a ping event. You don’t subscribe to ping: a test is sent whatever events you chose. A test is refused while the webhook is turned off.

Events

Event Sent when
alarm.opened A temperature, humidity or door alarm opens
alarm.escalated An alarm’s level rises, for example from caution to warning
alarm.muted An alarm is muted
alarm.unmuted A muted alarm is unmuted
alarm.closed An alarm ends
door.left_open A door alarm opens (sent as well as its alarm.opened)
door.closed A door alarm ends (sent as well as its alarm.closed)
sensor.offline A sensor stops reporting
sensor.online A sensor starts reporting again
gateway.offline The site’s hub or tablet goes offline. One event per outage
gateway.online The hub or tablet comes back
ping A test sent from the dashboard

A door alarm sends both alarm.opened and door.left_open, so subscribe to whichever suits you.

Many sensors at once. When a whole gateway goes offline, many sensors can go offline together. Past 50 sensor events at one site in a minute, the rest are not sent one by one. Once that minute ends, the sensors that went offline come as one sensor.offline with a count of how many they were, and any sensor.online among them is dropped. So to track each sensor’s state, take its next sensor.offline or sensor.online, or GET /sites/{siteId}/sensors, as the truth.

Payload

Every event has the same shape. alarm is the alarm as this change left it, with the same fields as its entry in GET /sites/{siteId}/alarms, so you can use one parser for both. sensor.name is the name of the unit the sensor is on, as in /sensors.

{
  "id": "evt_3b241101-e2bb-4255-8caf-4136c566a962",
  "type": "alarm.closed",
  "createdAt": "2026-10-12T01:02:03.000Z",
  "apiVersion": "v1",
  "data": {
    "site": { "id": 1300, "name": "Main Street" },
    "alarm": {
      "id": 41,
      "siteId": 1300,
      "category": "temperature",
      "level": "warning",
      "status": "closed",
      "sensorId": 3,
      "unitId": 4,
      "sensorName": "Walk-in freezer",
      "openedAt": "2026-10-12T00:00:00.000Z",
      "mutedAt": "2026-10-12T00:30:00.000Z",
      "closedAt": "2026-10-12T01:00:00.000Z",
      "closeReason": "telemetry_in_range"
    },
    "sensor": { "id": 3, "name": "Walk-in freezer", "kind": "temperature" }
  }
}
  • id is unique per event and the same on every retry. createdAt is when Thermalog recorded the event.
  • sensor.kind is temperature, humidity or door.
  • A gateway event has "sensor": null, and its alarm has the category gateway with sensorId, unitId and sensorName set to null.
  • A summary of sensors gone offline has "alarm": null, "sensor": null and a count. Its createdAt is when the summary was built:
{
  "id": "evt_9c5e7a2d-1f3b-4c8e-a6d4-2b7f0e1c3a59",
  "type": "sensor.offline",
  "createdAt": "2026-10-12T02:15:00.000Z",
  "apiVersion": "v1",
  "data": {
    "site": { "id": 1300, "name": "Main Street" },
    "alarm": null,
    "sensor": null,
    "count": 37
  }
}
  • A ping has site, alarm and sensor all null.
  • Payloads carry site and sensor names, values, times and ids, never personal details. The reference lists every field under “Webhooks (events you receive)”.

Each request carries these headers:

Header Value
Content-Type application/json
User-Agent Thermalog-Webhooks/1
X-Thermalog-Event The event type, for example alarm.closed
X-Thermalog-Event-Id The event’s id, for example evt_3b241101-…
X-Thermalog-Delivery This delivery’s number. Retries of the delivery keep the same number
X-Thermalog-Signature t=<unix seconds>,v1=<signature> (see below)

Verifying signatures

Check every request before you trust it. v1 is the hex HMAC-SHA256 of <t>.<body>, keyed with your webhook’s signing secret, where t is the timestamp from the same header and body is the raw request body. Use the secret exactly as the dashboard showed it, the whole whsec_… text.

  1. Read t and every v1 value from X-Thermalog-Signature. Accept the request if any v1 matches.
  2. Compute the HMAC over the raw bytes of the body, before any JSON parsing. Re-encoded JSON will not match.
  3. Compare in constant time.
  4. Refuse a t more than 5 minutes from your clock, so an old request cannot be replayed. Every attempt, retries included, is signed afresh with the time it was sent.

Node.js (Express):

const crypto = require('node:crypto');
const express = require('express');

const SECRET = process.env.THERMALOG_WEBHOOK_SECRET;
const TOLERANCE_SECONDS = 5 * 60;

function verifySignature(secret, header, rawBody, now = Date.now() / 1000) {
  if (!header) return false;
  let t = null;
  const signatures = [];
  for (const part of header.split(',')) {
    const [key, value] = part.trim().split('=');
    if (key === 't') t = Number(value);
    else if (key === 'v1' && value) signatures.push(value);
  }
  if (!Number.isInteger(t) || signatures.length === 0) return false;
  if (Math.abs(now - t) > TOLERANCE_SECONDS) return false;
  const expected = crypto
    .createHmac('sha256', secret)
    .update(`${t}.`)
    .update(rawBody)
    .digest();
  return signatures.some((sig) => {
    const given = Buffer.from(sig, 'hex');
    return given.length === expected.length && crypto.timingSafeEqual(given, expected);
  });
}

const app = express();

app.post('/thermalog/webhook', express.raw({ type: '*/*' }), (req, res) => {
  if (!verifySignature(SECRET, req.get('X-Thermalog-Signature'), req.body)) {
    return res.sendStatus(400);
  }
  const event = JSON.parse(req.body);
  res.sendStatus(204); // reply first, then do the work
  console.log(event.type, event.id);
});

app.listen(3000);

Python (Flask):

import hashlib
import hmac
import json
import os
import time

from flask import Flask, abort, request

SECRET = os.environ["THERMALOG_WEBHOOK_SECRET"]
TOLERANCE_SECONDS = 5 * 60


def verify_signature(secret: str, header: str, raw_body: bytes, now=None) -> bool:
    t = None
    signatures = []
    for part in (header or "").split(","):
        key, _, value = part.strip().partition("=")
        if key == "t":
            t = value
        elif key == "v1" and value:
            signatures.append(value)
    if t is None or not t.isdecimal() or not signatures:
        return False
    if now is None:
        now = time.time()
    if abs(now - int(t)) > TOLERANCE_SECONDS:
        return False
    expected = hmac.new(
        secret.encode(), t.encode() + b"." + raw_body, hashlib.sha256
    ).hexdigest()
    return any(hmac.compare_digest(expected.encode(), sig.encode()) for sig in signatures)


app = Flask(__name__)


@app.post("/thermalog/webhook")
def thermalog_webhook():
    raw_body = request.get_data()
    if not verify_signature(SECRET, request.headers.get("X-Thermalog-Signature", ""), raw_body):
        abort(400)
    event = json.loads(raw_body)
    print(event["type"], event["id"])
    return "", 204

Test vector. Check your code against these known-good values before you go live:

Input Value
Secret whsec_test_secret_do_not_use
t 1760000000
Body {"id":"evt_00000000-0000-4000-8000-000000000000","type":"ping"}
Header t=1760000000,v1=7879b987cd64c991bee068279b73f04b8997719cb53a26930f474459a15b883b

Add these lines below the code above. They pass “now” as 1760000000, so the 5-minute check holds, and must print true and True:

const body = Buffer.from('{"id":"evt_00000000-0000-4000-8000-000000000000","type":"ping"}');
const header = 't=1760000000,v1=7879b987cd64c991bee068279b73f04b8997719cb53a26930f474459a15b883b';
console.log(verifySignature('whsec_test_secret_do_not_use', header, body, 1760000000));
body = b'{"id":"evt_00000000-0000-4000-8000-000000000000","type":"ping"}'
header = "t=1760000000,v1=7879b987cd64c991bee068279b73f04b8997719cb53a26930f474459a15b883b"
print(verify_signature("whsec_test_secret_do_not_use", header, body, now=1760000000))

Rotating the secret replaces it at once, with no overlap: from then on every delivery is signed with the new secret only, and the old one no longer verifies. Put the new secret into your receiver straight away. Any delivery your receiver refuses in the meantime is retried on the schedule below.

Delivery and retries

  • Reply fast. Answer with any 2xx status within 10 seconds. Do slow work after you reply, or in a queue. Anything else is a failed attempt, a redirect (3xx) included: redirects are not followed. We read at most 16 KB of your reply and discard it.
  • Retries. A failed delivery is tried again after 1 minute, 5 minutes, 30 minutes, 2 hours and 12 hours. If that last try fails too, the delivery is given up on.
  • At least once. The same event can reach you more than once, for example when your server handled it but the reply was lost. Store each event’s id and ignore one you have already handled.
  • Order. Events come in no set order. Use createdAt to put them in order.
  • Backlog. If 1,000 deliveries are already waiting for one webhook, new events for it are dropped until it catches up.
  • Turned off automatically. A webhook is turned off, and its owner emailed, after 20 deliveries in a row are given up on, or after 24 hours of continuous failure. A failure more than 13 hours after the one before starts a new run, so occasional failures on quiet days never add up to 24 hours.
  • Turning a webhook off, by hand or automatically, means what it had waiting is not sent. Turning it on again clears its failures, and you can then retry the deliveries that were waiting when it was turned off. Events while it is off are not kept for it.
  • Delivery history. The dashboard lists each webhook’s recent deliveries, newest first, with their status, attempt count and last error. You can retry a failed or given-up delivery from there.
  • Ownership. Like a key, a webhook belongs to the Admin who created it and follows the same site rules: it only receives events for sites its owner could read with a key.

Webhook URLs

  • The URL must use https, on port 443 or 8443, with no user name or password in it, and be at most 2,048 characters.
  • Thermalog’s own hosts and their subdomains are refused, and so are the addresses they resolve to.
  • Every address the host resolves to must be public: private, loopback, link-local (cloud metadata), carrier-grade NAT, multicast, reserved and documentation ranges are refused, as are IPv4 addresses wrapped in IPv6.
  • This is checked again before every attempt, and the request goes to the address that was checked, not to a fresh DNS answer.

Changelog

v1 (12 October 2026). The first release of the Thermalog API: API keys; read access to sites, sensors, readings and alarms; and webhooks for alarm, door, sensor and gateway events, signed with HMAC-SHA256.

Questions or a feature you need? Email info@thermalog.com.au.