Pharmacy guide

Does a Pharmacy Need Temperature Monitoring?

What QCPP and the Strive for 5 vaccine storage guidelines expect from a pharmacy fridge, what twice-daily checks miss, and what continuous monitoring costs.

By Abid Khan, founder · 12 October 2026 · 5 min read

Short answer

Yes. A pharmacy storing vaccines must keep them at +2°C to +8°C and record the fridge temperature twice a day under the national Strive for 5 guidelines, and QCPP accreditation looks at cold chain records too. Manual checks cannot see nights and weekends; continuous monitoring with SMS alerts covers those hours.

A pharmacy fridge can hold several thousand dollars of vaccines and medicines, some of them hard to replace at short notice. Most pharmacists already record the temperature twice a day. The question is whether that is enough, and what a monitoring system adds that a clipboard does not.

This guide sets out what the guidelines expect, where manual recording runs out, and what continuous monitoring changes and costs.

What QCPP and Strive for 5 expect

Two sets of expectations apply to most Australian community pharmacies.

The National Vaccine Storage Guidelines, Strive for 5. Published by the Australian Government Department of Health, these are the reference for anyone storing vaccines (health.gov.au, Strive for 5). In general terms they ask for:

  • vaccines stored between +2°C and +8°C, aiming for +5°C;
  • a purpose-built vaccine refrigerator, not a domestic or bar fridge;
  • the current, minimum and maximum temperature recorded manually at least twice a day, with the thermometer reset after each reading;
  • where a data logger is fitted, the data downloaded and reviewed at least weekly;
  • a written procedure for a cold chain breach, and staff who know it.

The Quality Care Pharmacy Program (QCPP). QCPP is the Pharmacy Guild’s accreditation program, and its standards include cold chain management. Assessors look for evidence that fridges holding medicines and vaccines are monitored, that the records are complete, and that excursions were noticed and acted on. Check the current QCPP requirements for the detail that applies to your pharmacy.

Neither asks for a particular brand of equipment. Both ask you to show that the temperature stayed in range, and what you did when it did not. Our pharmacy fridge temperature monitoring page shows how that record looks in a monitoring dashboard.

What the manual record misses

A twice-daily check proves the fridge was in range at opening and at close. A min/max thermometer adds the extremes since the last reset. That is a sound routine, and it still leaves three gaps.

  • When and for how long. A maximum of 11°C on Monday morning tells you the fridge went out of range. It does not tell you whether that was ten minutes during a restock on Saturday or six hours overnight. A breach report will ask for both.
  • Weekends and public holidays. A pharmacy closed on Sunday has no check between Saturday afternoon and Monday morning. That is the longest stretch of the week without anyone looking.
  • The 2am failure. Compressors, power supplies and door seals do not fail on a roster. A fridge that stops at 2am is found at opening, by which point the stock has been out of range for hours.

The weekly data logger review helps with the first gap, but only after the event. By the time the download shows the excursion, the stock has already been out of range.

Our free Strive for 5 vaccine fridge temperature chart is laid out for the twice-daily record. Keep using it whatever else you install.

What continuous monitoring changes

A wireless sensor in the fridge sends a reading at a set interval to a gateway, which passes it to a cloud dashboard. Three things change.

Someone hears about it at 2am. When a reading crosses the limit you set, an SMS and email go to the people you nominate, at any hour. A pharmacist who lives ten minutes away can move stock to a backup fridge before it is lost.

The history answers the breach questions. The dashboard keeps every reading with a timestamp, so you can see when the excursion started, how high it went and when the fridge recovered. History is kept for two years and can be exported as a report.

The weekly review takes minutes. Instead of downloading a logger and reading a graph, you open the dashboard and look at the week.

It does not change two things. Strive for 5 still asks for the manual check twice a day, and monitoring does not turn a domestic fridge into a vaccine refrigerator. The vaccine temperature monitoring page covers how the two fit together.

On accuracy: Thermalog’s Tesen sensor uses the Texas Instruments TMP117, specified to ±0.1°C maximum chip error from −20°C to 50°C. That is a chip-level figure, not an individual calibration certificate for the sensor.

When a cold chain breach happens

Strive for 5 sets out what to do when a vaccine fridge goes outside +2°C to +8°C; check the guidelines for exactly how it defines a breach. In general terms:

  1. Keep the affected vaccines refrigerated at +2°C to +8°C. Do not discard them.
  2. Isolate them and mark them “do not use” until you have advice.
  3. Record the minimum and maximum temperatures and how long the fridge was out of range.
  4. Contact your state or territory health department immunisation unit for advice on the stock.
  5. Find and fix the cause before you use the fridge again.

Step 3 is where a manual record struggles and a monitored one does not. The health department will ask how long the stock was out of range, and a timestamped history answers that directly. The pharmacy fridge monitoring page shows the alert and record settings.

So, does every pharmacy need it?

Every pharmacy storing vaccines or refrigerated medicines needs temperature monitoring of some kind. The guidelines say so, and the twice-daily record is the minimum.

Whether you need continuous monitoring with alerts depends on what is in the fridge and how long it is left alone. A pharmacy that is closed on Sundays, stocks vaccines for an immunisation service, or holds high-value refrigerated medicines is the case it was designed for. One night of lost stock can cost more than several years of monitoring. The vaccine temperature monitoring page has the details for immunisation services.

What it costs

Thermalog uses a wireless Tesen sensor in each fridge, reporting to one gateway per pharmacy.

Setup Upfront, ex GST Monthly
One fridge: Cloud Gateway + 1 sensor $540 $4
Two fridges: Cloud Gateway + 2 sensors $719 $8
Starter Kit: Cloud Gateway + 3 sensors $898 $12

The Cloud Gateway is $361 ex GST, connects by Wi-Fi or Ethernet and serves up to 32 devices. Each sensor is $179 ex GST, and monitoring is $4 a month per sensor for the dashboard, records and SMS and email alerts. A door contact for the fridge is $51 ex GST plus $2 a month. All hardware has a 2-year warranty and there is no lock-in on monitoring.

See pharmacy fridge temperature monitoring for the full setup, or the pricing page for every price.

Questions people ask

How often should a pharmacy fridge temperature be recorded?

Strive for 5 asks for the current, minimum and maximum temperature of a vaccine fridge to be recorded manually at least twice a day, even when a data logger is fitted, and for the logger to be downloaded and reviewed at least weekly. The same routine is sensible for any fridge holding medicines labelled for 2–8°C storage.

What temperature should a pharmacy vaccine fridge be?

Between +2°C and +8°C, aiming for +5°C, the midpoint. Strive for 5 calls for a purpose-built vaccine refrigerator rather than a domestic, bar or commercial food fridge.

Does continuous monitoring replace the twice-daily manual check?

No. Strive for 5 still asks for the manual record twice a day. Continuous monitoring adds what the manual check cannot give you: alerts out of hours, and a timestamped history showing when an excursion started and how long it lasted.

What should a pharmacy do after a cold chain breach?

Follow Strive for 5 and your own cold chain procedure. In general terms: keep the affected stock refrigerated at +2°C to +8°C, isolate it and mark it not for use, do not discard it, record the temperatures and times, and contact your state or territory health department for advice.

How much does pharmacy fridge monitoring cost?

With Thermalog, one fridge needs a Cloud Gateway at $361 ex GST and a Tesen sensor at $179 ex GST, so $540 ex GST upfront, plus $4 a month for monitoring and alerts. Each extra fridge adds $179 ex GST and $4 a month.

Stop doing this with a clipboard.

Automated logging, temperature alerts, audit-ready records — sized for your fridges in two minutes.

Build my system →