Temperature and humidity monitoring for the rooms your stock lives in.
A wireless sensor records the temperature and relative humidity of a dry store, dispensary, server room or archive every few minutes, alerts you by SMS, email or app when a limit is crossed, and keeps the record.
Air temperature from −20 °C to 60 °C and relative humidity across 0–100% RH, specified at ±0.2 °C temperature; ±2% RH humidity.
A reading every few minutes to the dashboard, with the current values on the sensor's own LCD for anyone in the room.
Upper and lower limits per sensor for both measurements, an alarm delay, and alerts by SMS, email and the Android or iOS app.
History per room, exportable for a period, kept as the record.
Confirm the environment
Near −20 °C the temperature deviation may reach ±0.7 °C and battery life shortens, so this sensor suits rooms and stores; fridges and freezers use the Tesen sensor. IP65 splash protection does not mean it can be immersed or left where condensation forms on the case.
Monitoring does not control temperature or humidity. Remote records and alerts require gateway power, internet and wireless coverage.
Rooms where temperature and humidity need a record.
Dry stores and stockrooms
Flour, grain, packaging and canned goods keep longest cool and dry. Most food safety programs set a dry store limit around 25 °C and 60% relative humidity to keep stock and packaging out of mould and pest range, and a dated record shows the store was kept that way.
Medicine and consumable storage
Most medicines are labelled “store below 25 °C”, and pharmacies, clinics and aged care homes are expected to show the dispensary and stock rooms stayed there through summer. A sensor on the shelf records it without a daily walk-round.
Server and comms rooms
Equipment makers and ASHRAE put the recommended envelope at roughly 18 to 27 °C with humidity kept below about 60%. An alert at 30 °C reaches the on-call phone before a failed air conditioner becomes a failed server.
Archives, museums and galleries
Paper, film, textiles and timber want stable conditions, typically 16 to 22 °C and 40 to 55% relative humidity depending on the material, with swings mattering more than the number. A continuous record shows the swings a weekly check never sees.
Warehouses and workshops
Adhesives, paints, electronics and some chemicals have a storage band on the label. One sensor per zone shows which corner of the building drifts in the afternoon sun and whether the night-time humidity is condensing on stock.
Offices, classrooms and clinics
Comfort and compliance checks for indoor air: a sensor per floor or wing gives a record of room temperature and humidity for facilities teams without a site visit.
The limits above are the common ranges from Australian food safety programs, medicine labels, ASHRAE and collection-care guidance. Set each sensor's limits from your own program or the product label, and keep the record with it.
Setting limits
From a reading to a useful alert.
Set the upper limit a little inside the number you must not exceed, so the alert arrives while there is time to act: 24 °C for a store that must stay below 25 °C, 28 °C for a server room that fails at 30 °C. Add a delay of a few minutes so a door opening or a brief defrost of a nearby unit does not page anyone. For humidity, alert on a sustained reading rather than a spike; condensation and mould are about hours, not seconds. Name the person who responds and have them log what they did against the alarm, so the record shows the problem and the fix together.
If you already monitor fridges with Thermalog, the humidity sensor joins the same gateway and dashboard; see how the system fits together.
A different environment?
For greenhouses, manufacturing areas, specialist materials or challenging conditions, tell us the expected temperature, humidity, exposure and reporting requirements. We will discuss suitability before recommending hardware.
Outdoor exposure, direct contact with materials, immersion and specialist certification are not implied by this page.
What is a temperature and humidity monitoring system?
A wireless sensor in each room or store that measures air temperature and relative humidity every few minutes and sends the readings through a gateway to a cloud dashboard. You set an upper and lower limit for each sensor; when a reading crosses it, the people you choose get an SMS, email or app alert. The readings are kept as the record for an auditor, a landlord or an insurer.
What humidity is too high for a dry store?
Mould grows on most food packaging and dry goods once the air sits above about 60 to 65% relative humidity for long periods, and pests thrive in warm, damp stores. Most Australian food safety programs set the dry store at or below 25 °C and 60% RH and record it, though the number belongs in your own program, not in a universal rule.
How accurate is the sensor?
The Temperature & Humidity Sensor is specified at ±0.2 °C temperature; ±2% RH humidity, measures −20 °C to 60 °C and 0–100% RH, and shows both readings on a 2.2-inch LCD. Near −20 °C the temperature deviation can reach ±0.7 °C and battery life shortens, so it suits rooms, not freezers; use the Tesen sensor for fridges and freezers.
Where should the sensor go?
At the height the stock sits, away from doors, vents, direct sun and heat sources such as a server rack exhaust, and mounted at 2 m or lower on its magnetic back. In a large room put one sensor where conditions are worst (the corner furthest from the air conditioning, the top shelf) and one where they are typical. Avoid placing it where condensation can form on the case: the enclosure is IP65 splash-protected, not waterproof.
Can it control the air conditioning or a dehumidifier?
No. Thermalog monitors and alerts; it does not switch equipment. The value is knowing within minutes that a room has drifted, with a record of how long it stayed out of range, so the right person can act.
What does it cost?
The sensor is $156 ex GST and remote monitoring is $4 a sensor a month, with no contract. It needs a Thermalog gateway on site, which you may already have if you monitor fridges; otherwise a Cloud Gateway is $361 ex GST. Every price is on the pricing page.